Skip to content
PS-HRK-24 hotel room energy kit with two ceiling mmWave sensors, door magnetic contact and room controller
CEFCCRoHSISO 9001
Answer Snapshot

Qualification facts buyers can extract quickly

PS-HRK-24 is a per-room retrofit kit: two 24GHz ceiling mmWave presence sensors for bedroom and bathroom, a door magnetic contact that runs off the lock battery, and a controller inside the existing switch box. Local operation, no cloud platform.

Last Updated
11/20/2026
Who it is for
Hotel owners and operations directors measuring room-level energy cost, Hospitality contractors and integrators retrofitting existing properties, Serviced apartment and resort operators without a central building management system
Use cases
Guest room power control on door entry and true vacancy, Air conditioning and lighting shutoff when a room is empty, Bathroom lighting and exhaust control based on presence, Room status for housekeeping without a card slot
MOQ
500 pcs for standard models; negotiable for OEM/ODM
Lead time
Samples 3-5 days / Mass production 7-10 days
Certifications
CE, FCC, RoHS, ISO 9001
Served markets
Worldwide
Export context
Supplied as a per-room retrofit kit; projects are scoped by room count, door lock model and the wiring available at the in-room switch box
Next step
Send the door lock brand and model, a photo of the in-room switch box and the room count; we will return a bill of materials and a pilot plan.

Product overview

What the PS-HRK-24 hotel room energy kit is

PS-HRK-24 is a per-room retrofit kit from PresenceSensor for hotel guest rooms. One set contains two 24GHz ceiling mmWave presence sensors (bedroom and bathroom), one door magnetic contact that sits inside the existing lock body and runs off the lock battery, and one room controller that mounts inside the switch box already in the room. The kit switches room power on when the door opens and off only when both sensors agree the room is empty. It works without a cloud platform, a PMS integration or a new network. Kit pricing starts at USD 36 per room at 500+ sets, MOQ is 500 sets, samples ship in 3–5 days, and mass production takes 7–10 days.

What is in one set

Model Component Where it goes Power
PS-SEN-BED-24 ×1 / PS-SEN-BATH-24 ×1 24GHz ceiling mmWave presence sensor Bedroom ceiling and bathroom ceiling, Ø86 mm cut-out DC 5V
PS-DC-01 ×1 Door magnetic contact, 2 × 4 cm Inside the gap in the existing lock body Door lock battery
PS-RC-01 ×1 Room controller Inside the existing in-room switch box Mains at the switch

Sensors and controller communicate inside the room. The door contact does not need configuring or pairing at the lock: it reports the door opening, and the controller switches room power as soon as that signal arrives.

Detection performance

Parameter Value
Technology 24GHz wideband mmWave radar, FMCW
Motion detection Up to 10 m
Micro-motion and breathing detection Up to 2.5 m
Field of view 120°
Switch-on latency Door contact reports within about one second
Switch-off rule Both sensors report empty
Configuration Occupancy hold time adjustable per property

The 2.5 m micro-motion range is the number that decides whether a guest sleeping in a queen or king bed keeps the room occupied. Most mmWave presence sensors on the market reach 1.5 m or less, which leaves the far side of the bed uncovered.

Which door locks it fits

PS-DC-01 is a magnetic contact, not a lock or a lock interface. It is 2 × 4 cm and fits into the free space inside the lock body of common electronic hotel locks, including Onity, VingCard and Assa Abloy models, drawing power from the lock's own battery. No drilling, no lock replacement and no communication module inside the lock are required. If the lock body has no free 2 × 4 cm gap, the contact can be fitted at the frame edge instead.

How much does a room cost?

Indicative kit pricing is USD 43 per room below 200 sets, USD 39 per room at 200–500 sets, and USD 36 per room at 500+ sets. One set covers a standard guest room: two ceiling presence sensors, the door contact and the room controller.

The final quotation depends on three details: the door lock model (contact placement), the wiring available at the in-room switch box (controller placement) and the room count. Send those three details and you get a per-room bill of materials with a pilot plan. Standard MOQ is 500 sets; pilot floors below that are quoted at the below-200 tier.

How long does installation take?

Each room needs two ceiling cut-outs (Ø86 mm) for the sensors, the door contact fitted into the lock body, and the controller wired into the switch box. A two-person team typically completes a floor of standard rooms in a day, and the kit is commissioned room by room without a central server.

Frequently asked questions

Does the room need internet access? No. Sensors, door contact and controller communicate inside the room, and the room switches on and off without any network connection. A property can add a gateway if it wants room status in a building system, but the energy function does not depend on it.

What happens if a guest is asleep when the room goes quiet? The sensors keep reporting presence. 24GHz mmWave radar detects breathing-level micro-motion to 2.5 m, so a sleeping guest continues to read as present and the room is not switched off.

Will it work with the locks we already have? In most cases yes. The door contact only needs a 2 × 4 cm gap inside the lock body and takes power from the lock battery; it does not talk to the lock electronics. Send the lock model and we will confirm placement before quoting.

Does it integrate with our PMS? The kit is deliberately local: it does not require PMS integration to control room power. Housekeeping or front-desk status can be added through an optional gateway, but the energy-saving function runs without one.

What is the minimum order? 500 sets (one set per room) for standard production. Pilot floors below 500 sets are negotiable.

How is it certified for export? Sensors carry CE, FCC and RoHS documentation, and the manufacturing site is ISO 9001 certified. Certificates are supplied with the shipment.

Key selling points

Power follows the guest, not the card slot

The door contact switches the room on the moment the door opens, and the room only powers down after both ceiling sensors agree nobody is left inside — including a guest who is asleep, reading or in the bathroom.

Bathroom covered by its own sensor

A dedicated sensor in the bathroom removes the most common false-vacancy case in hotel energy projects: a guest behind a closed door that the bedroom sensor cannot see.

Breathing-level micro-motion

24GHz mmWave radar detects the micro-motion of breathing to 2.5 m, so a sleeping guest keeps the room in the occupied state. PIR and narrow-band motion sensors fail exactly here.

Fits the door lock and the switch box that are already there

The door contact is a 2 × 4 cm magnetic contact that draws power from the lock battery, and the controller sits in the existing in-room switch box. No new wiring runs, no lock replacement.

Local by design

Sensors, door contact and controller communicate inside the room. There is no server to host, no guest account to configure and no internet dependency for the room to switch on and off.

Technical specifications

Kit model PS-HRK-24
Sensors included PS-SEN-BED-24 ×1 + PS-SEN-BATH-24 ×1 24GHz ceiling mmWave presence sensor
Door contact 1 × PS-DC-01 magnetic contact, 2 × 4 cm, powered by the lock battery
Controller 1 × PS-RC-01 room controller, inside the existing switch box
Detection 24GHz FMCW radar, motion to 10 m, micro-motion and breathing to 2.5 m
Field of view 120° from a standard ceiling height
Switch-on trigger Door contact reports the opening within one second
Switch-off rule Only after both sensors agree nobody is left in bedroom and bathroom
Ceiling cut-out 86 mm per sensor
Sensor power DC 5V
Controller power Mains available at the existing switch box
Network dependency None — sensors, contact and controller talk inside the room
Door lock compatibility Any lock body with a free 2 × 4 cm gap
Operating temperature 10 to +50°C

Request pricing, samples, or customization details

Leave the application, quantity, and target market information so the sales team can respond with a practical next step.

Selected product: PS-HRK-24 Hotel Room Energy Kit — Two mmWave Sensors, Door Contact and Room Controller
Step 1
Quick brief

Start with contact details, quantity, and the shortest useful summary of your requirement.

Step 2
Add specs and trade details

Use the optional second step when you already know destination, target terms, certifications, or packaging needs.

Contact details
Project summary
No file selected

Upload reference photos, datasheets, or requirement sheets.

Step 2
Add specs and trade details

Use the optional second step when you already know destination, target terms, certifications, or packaging needs.

Add technical details
Commercial terms
Technical requirements

The second step is optional. Submit after step one if you need to start the conversation quickly.

Structured RFQs help the team review feasibility, pricing, sample routes, and export requirements faster.

We respect your privacy. Response within 24 business hours.

Ready for RFQ

Share your product requirements and get a practical next step

Send your drawings, target quantity, and timeline. Our sales engineering team will respond within 24 business hours with a practical next step, a quote, or a sample plan.

Send a quick inquiry

Tell us what you need — room size, target volume, timeline. We respond within 24 business hours.

A clear brief helps the team reply within one business day with the right catalog, sample route, or quotation next step.