跳到正文
吸顶式60GHz毫米波人体存在传感器,白色嵌入式外壳
CEFCCRoHSISO 9001
答案速览

帮助买家快速提取的资格事实

60GHz(57–64GHz)毫米波吸顶存在传感器,7GHz带宽实现2.1cm距离分辨率,可检测呼吸级微动。120°探测角,DC5V供电,Zigbee 3.0组网。适用于酒店客房入住状态检测、客房清洁排班与空调节能等商业自动化场景,静态人体存在检测精度出众,人在场时绝不误报为离开。

最后更新
2026/7/1
适合谁
连锁酒店及酒店业AV/IT集成商, 负责客房自动化选型的智能楼宇工程承包商
适用场景
酒店客房入住检测,用于客房清洁排班与空调节能, 智能办公会议室预订及基于占用状态的空调控制, 度假租赁与服务式公寓的存在感应自动化, 医疗与养老场景的房间占用检测及呼吸监测
MOQ
500 pcs for standard models; negotiable for OEM/ODM
交期
Samples 3-5 days / Mass production 7-10 days
资质体系
CE, FCC, RoHS, ISO 9001
服务市场
Worldwide (CE/FCC certified)
出口语境
OEM ODM项目设计,满足其对高分辨率60GHz
下一步
携您的网关申请样品,在实际目标房间尺寸下验证微动与呼吸检测性能。

产品概述

为什么选择60GHz存在传感器实现卓越检测精度

这款60GHz毫米波吸顶人体存在传感器是一款Zigbee存在传感器,采用57–64GHz V频段毫米波雷达核心与7GHz带宽,可检测真实的人体存在——包括静坐或熟睡的住客。它为选型人员提供基础存在传感器无法企及的能力:以2.1cm距离分辨率实现可靠的静态人体检测,在住客睡觉、静坐或阅读时将房间持续保持为“有人”状态。与只能捕捉运动的PIR传感器不同,这款存在传感器只要房间内有人就会上报“有人”,甚至能感知呼吸级微动。对于以精细检测精度为优先的酒店客房入住检测、客房清洁排班和空调节能场景,它是最合适的存在传感器。

60GHz与24GHz毫米波存在传感器对比

存在探测器的对比十分关键:PIR存在探测器依靠人体与背景环境的热对比触发,在两种有充分记录的场景中会失效——一是人员静止不动(睡觉、阅读、伏案工作),二是夏季环境温度接近体温的房间。这款60GHz毫米波存在传感器的表现优于PIR和窄带24GHz存在探测器。7GHz V频段雷达核心以2.1cm距离分辨率检测微动与呼吸,在住客睡觉时将房间持续保持为“有人”状态——这种表现是窄带24GHz存在传感器以同等置信度无法企及的。酒店客房是运动传感器的经典失效场景:住客躺在床上阅读或看电视时动作极少,基于PIR的系统会误报“无人”并切断灯光或空调。毫米波雷达不受环境温度影响。我们的60GHz毫米波存在传感器可在2.5m范围内检测到呼吸带来的微动——7GHz带宽使其距离分辨率余量约为窄带24GHz传感器的28倍。57–64GHz工作频段还能抵御密集酒店部署中其他常见设备的干扰,提升静态存在判别能力。

检测性能

参数 数值
频段 57–64GHz(V频段)
带宽 7GHz
最大运动检测距离 10m
最大微动/静态检测距离 2.5m
呼吸检测 支持
探测角度 120°

10m运动检测距离让单个吸顶存在传感器即可覆盖大型酒店客房和会议室,而2.5m微动检测距离确保熟睡或静坐的住客绝不会被漏检——这款存在传感器检测的是呼吸,而不仅仅是运动。吸顶安装时,120°视场角可实现全屋覆盖。这款60GHz存在传感器的7GHz带宽带来精细的微多普勒灵敏度,使静态人体检测更加可靠。在静态占用检测精度上,这款存在传感器优于PIR存在传感器和窄带24GHz存在传感器。

安装与供电

这款存在传感器嵌入安装于标准天花板开孔中。DC5V低压供电简化了OEM集成——存在传感器可嵌入带电灯具、USB供电装置或带电池备援的楼宇系统。对于改造项目,存在传感器随附DC5V电源适配器。作为Zigbee存在传感器,它采用可扩展至整层酒店部署的Zigbee 3.0 mesh组网,不受WiFi拥堵影响,并兼容Tuya Smart Life及任何标准Zigbee 3.0网关——因此这款存在传感器可无缝接入现有智能楼宇系统,无厂商锁定风险。

应用场景

  • 酒店客房:60GHz存在传感器为客房清洁、空调节能回设与免打扰智能逻辑提供客房占用状态——住客小憩时再也不会误报“无人”。能够检测呼吸的存在传感器确保房间在住客离开前始终保持“有人”状态。
  • 会议室:为预订系统提供实时占用数据,并实现基于存在传感器的灯光/空调控制。这款存在传感器可避免有人在房间内时系统却显示“可预订”的重复预订问题。
  • 服务式公寓与度假租赁:存在传感器支持自动退房检测与基于存在状态的场景联动——60GHz存在传感器检测到人员离开后触发门锁/空调自动化。
  • 养老看护与医疗:带呼吸检测的房间占用监测——这款存在传感器无需摄像头或可穿戴设备即可实现无感监测。

为什么选择这款60GHz存在传感器

为酒店和商业项目选择合适的存在传感器至关重要。与其他存在传感器相比,这款60GHz存在传感器具备三大优势:(1) 采用7GHz带宽的V频段毫米波检测,能在PIR存在传感器失效的场景中感知呼吸;(2) Zigbee 3.0 mesh可扩展至数百个房间——构建不受WiFi拥堵影响的存在传感器网络;(3) DC5V低压设计简化了这款存在传感器的OEM集成。无论您需要酒店客房吸顶存在传感器,还是办公自动化存在传感器,这款60GHz存在传感器都能以呼吸级灵敏度实现真实占用检测。存在传感器是任何智能楼宇存在感知部署的核心——而这台60GHz存在传感器专为高精度而生。

认证与出口

已通过CE、FCC和RoHS认证,可直接进口欧盟和美国市场——每台存在传感器均随附合规文件。ISO 9001制造体系确保每台存在传感器品质稳定一致。存在传感器样品3-5天内发货;60GHz存在传感器量产周期为7-10天,支持FOB深圳、CIF或DDP物流。达到起订量即可提供OEM贴牌、定制包装和协议定制服务——为您打造符合您规格要求的贴牌60GHz存在传感器。

Why choose a 60GHz presence sensor for premium accuracy

The Ceiling Mount mmWave Human Presence Sensor (60GHz) is a Zigbee presence sensor that detects true human presence — including a guest sitting still or sleeping — using a 57–64GHz V-band mmWave radar core with 7GHz of bandwidth. As a presence sensor, it gives specifiers what a basic presence sensor cannot: reliable stationary-occupant detection with 2.1cm range resolution, holding the room "occupied" while a guest sleeps, sits, or reads. Unlike PIR sensors that only catch movement, this presence sensor reports "occupied" as long as a person is in the room, and even senses breathing-level micro-motion. It is the right presence sensor for hotel room occupancy, housekeeping scheduling, and HVAC energy saving where fine detection accuracy is the priority.

60GHz vs 24GHz mmWave Presence Sensors

A presence detector comparison matters: PIR presence detectors trigger on body-against-background thermal contrast, and they fail in two well-documented scenarios — stationary occupants (sleeping, reading, desk work) and rooms where ambient temperature approaches body temperature in summer. This 60GHz mmWave presence sensor outperforms both PIR and narrow-band 24GHz presence detectors. The 7GHz V-band radar core detects micro-motion and breathing at 2.1cm range resolution, holding the room "occupied" while a guest sleeps — a presence detector behavior narrow-band 24GHz presence sensors cannot match with the same confidence. Hotel rooms are the classic failure case for motion sensors: a guest reading in bed or watching TV generates little movement, so PIR-based systems falsely report "vacant" and cut off lights or HVAC. mmWave radar is unaffected by ambient temperature. Our 60GHz mmWave presence sensor detects the micro-motion of breathing up to 2.5m — the 7GHz bandwidth gives it roughly 28× the range-resolution headroom of a narrow-band 24GHz sensor. The 57–64GHz operation also resists interference from other devices common in dense hotel deployments, improving static-presence discrimination.

Detection performance

Parameter Value
Frequency band 57–64GHz (V-band)
Bandwidth 7GHz
Max motion detection 10m
Max micro-motion / static detection 2.5m
Breathing detection Supported
Detection angle 120°

The 10m motion range covers large hotel rooms and meeting spaces from a single ceiling presence sensor, while the 2.5m micro-motion range ensures a sleeping or seated guest is never missed — the presence sensor detects breathing, not just movement. The 120° field of view provides full room coverage when the presence sensor is ceiling-mounted. The 7GHz bandwidth of this 60GHz presence sensor delivers the fine micro-Doppler sensitivity that makes stationary-occupant detection reliable. This presence sensor outperforms PIR presence sensors and narrow-band 24GHz presence sensors in static-occupancy accuracy.

Installation and power

The presence sensor flush-mounts into a standard ceiling cutout. DC5V low-voltage input simplifies OEM integration — the presence sensor can be embedded into powered fixtures, USB-powered installations, or battery-backed building systems. For retrofit projects, the presence sensor pairs with a supplied DC5V power adapter. As a Zigbee presence sensor, it uses Zigbee 3.0 mesh networking that scales to whole-floor hotel deployments without WiFi congestion, and it works with Tuya Smart Life and any standard Zigbee 3.0 gateway — so the presence sensor drops into existing smart-building stacks without lock-in.

Applications

  • Hotel rooms: the 60GHz presence sensor provides guest-room occupancy status for housekeeping, HVAC setback, and do-not-disturb intelligence — no more false "vacant" while a guest naps. A presence sensor that detects breathing ensures the room stays "occupied" until the guest leaves.
  • Meeting rooms: real-time occupancy for booking systems and presence-sensor-based lighting/HVAC control. The presence sensor prevents double-booked rooms showing as "available" when someone is inside.
  • Serviced apartments & vacation rentals: the presence sensor enables automated check-out detection and presence-based scenes — the 60GHz presence sensor detects departure and triggers lock/HVAC automation.
  • Elder care & healthcare: room occupancy with breathing detection — the presence sensor provides non-intrusive monitoring without cameras or wearables.

Why choose this 60GHz presence sensor

Choosing the right presence sensor matters for hotel and commercial projects. This 60GHz presence sensor offers three advantages over other presence sensors: (1) V-band mmWave detection with 7GHz bandwidth that senses breathing where PIR presence sensors fail; (2) Zigbee 3.0 mesh that scales to hundreds of rooms — a presence sensor network without WiFi congestion; (3) DC5V low-voltage design that simplifies OEM integration of the presence sensor. Whether you need a ceiling presence sensor for hotel rooms or a presence sensor for office automation, this 60GHz presence sensor delivers true occupancy detection with breathing-level sensitivity. The presence sensor is the core of any smart building presence sensor deployment — and this 60GHz presence sensor is built for accuracy.

Certifications and export

CE, FCC, and RoHS certified for direct import into EU and US markets — every presence sensor ships with compliance documents. ISO 9001 manufacturing ensures each presence sensor meets consistent quality. The presence sensor ships in 3-5 days for samples; mass production of the 60GHz presence sensor runs 7-10 days with FOB Shenzhen, CIF, or DDP logistics. OEM branding, custom packaging, and protocol customization are available at MOQ — your branded 60GHz presence sensor, built to your presence sensor specification.

核心卖点

静态人体检测,支持呼吸感知

这款60GHz存在传感器利用7GHz带宽检测静态占用状态,甚至能感知呼吸——这正是PIR存在传感器和窄带24GHz传感器失效的场景。住客睡觉、静坐或阅读时,房间始终保持"有人"状态,杜绝误报"无人"的触发。

10m运动检测,2.5m微动检测

这款存在传感器可检测最远10m的大幅运动和最远2.5m的微动(呼吸级),配合120°视场角——单个存在传感器即可覆盖大型酒店客房和会议空间。

高分辨率60GHz雷达核心

这款存在传感器采用57–64GHz V频段雷达核心,带宽达7GHz,可提供2.1cm距离分辨率和精细的微多普勒灵敏度,实现可靠的静态人体检测。

DC5V低压设计

DC5V低压输入简化了这款存在传感器的OEM集成,可嵌入带电灯具、USB供电装置或带电池备援的楼宇系统。针对改造项目,存在传感器随附电源适配器。

Zigbee 3.0 mesh组网

作为Zigbee存在传感器,它采用稳定的Zigbee mesh组网,可扩展至整层酒店部署而不受WiFi拥堵影响。这款存在传感器兼容Tuya Smart Life及任何标准Zigbee 3.0网关。

技术规格

Detection Technology mmWave radar
Frequency Band 57–64GHz
Bandwidth 7GHz
Max Motion Detection Range 10m
Max Micro-motion / Static Detection Range 2.5m
Breathing Detection Supported
Detection Angle 120
Detection Type Motion + micro-motion + static presence + breathing
Mounting Flush ceiling mount
Power Supply DC5V
Standby Power 0.5W
Communication Zigbee 3.0
Ecosystem Tuya Smart Life, compatible with Zigbee 3.0 gateways
Operating Temperature 10°C to +55°C
IP Rating IP54
Dimensions 86mm x 35mm
Housing Fire-retardant PC, white

获取报价、样品或定制方案

请尽量填写应用场景、数量、目标市场和时间要求,便于销售团队给出有用的下一步建议。

已选择产品: 60GHz毫米波吸顶人体存在传感器 — 静态与呼吸级检测的Zigbee存在传感器
步骤 1
快速简述需求

先填写联系方式、数量和最短但有用的项目背景,尽快启动首轮回复。

步骤 2
补充规格和贸易细节

如果已经明确目的地、贸易条款、认证或包装要求,可继续补充第二步信息。

联系方式
项目概要
未选择文件

可上传图纸、资料、参考图片或需求文档。

步骤 2
补充规格和贸易细节

如果已经明确目的地、贸易条款、认证或包装要求,可继续补充第二步信息。

补充技术细节
商务条款
技术要求

第二步为可选项。若想先快速发起沟通,填写完第一步即可提交。

结构化 RFQ 可以帮助团队更快完成可行性评估、报价、打样和出口要求确认。

我们尊重您的隐私,24 个工作小时内回复。

立即发起询盘

告知我们项目需求,获取明确的下一步

请发送房间尺寸、目标数量与时间表。我们的销售工程团队将在 24 个工作小时内回复,提供下一步建议、报价或打样方案。

快速发送询盘

告知我们您的需求——房间尺寸、目标数量、时间表。我们将在 24 个工作小时内回复。

项目背景越清晰,销售团队越容易在 1 个工作日内给出准确的目录、样品或报价下一步。